Parameter Description
Table 6-4
Table 6-4 Running parameter descriptions
No.
Parameter
Name
1
Offset mode
2
Output
enabled
Issue 12 (2019-01-15)
describes the PID module running parameters.
Function
Parameter
Value
Specifies the
Disabled
offset mode of
the PID module.
N/PE
PV/PE
Automatic
Specifies whether
Enable
the PID module
Copyright © Huawei Technologies Co., Ltd.
Operation Procedure
6. Choose Running Param. and press
Description
Set this parameter to Disable if the PID module is
not required.
Set this parameter to N/PE if the PID module is
required to use voltage output from the inductor
virtual midpoint N.
Set this parameter to PV/PE if the PID module is
required to use voltage output from the negative PV
terminal.
This mode is applicable only to SUN8000.
In the SUN2000, Automatic indicates the N/PE
offset mode.
Set this parameter to Enable to allow the PID
module output.