Huawei SmartLogger1000 User Manual page 197

Hide thumbs Also See for SmartLogger1000:
Table of Contents

Advertisement

SmartLogger1000
User Manual
No.
Parameter
10
Level-1 UV
protection
Level-1 UV
11
protection
time
Level-2 UV
12
protection
13
Level-2 UV
protection
time
14
Level-1 OF
protection
Level-1 OF
15
protection
time
Level-2 OF
16
protection
17
Level-2 OF
protection
time
18
Level-1 UF
protection
19
Level-1 UF
protection
time
20
Level-2 UF
protection
Level-2 UF
21
protection
time
Level-3 OV
22
protection
Issue 12 (2019-01-15)
Description
Specifies the level-1
undervoltage protection
threshold.
Specifies the level-1
undervoltage protection
duration.
Specifies the level-2
undervoltage protection
threshold.
Specifies the level-2
undervoltage protection
duration.
Specifies the level-1
overfrequency protection
threshold.
Specifies the level-1
overfrequency protection
duration.
Specifies the level-2
overfrequency protection
threshold.
Specifies the level-2
overfrequency protection
duration.
Specifies the level-1
underfrequency
protection threshold.
Specifies the level-1
underfrequency
protection duration.
Specifies the level-2
underfrequency
protection threshold.
Specifies the level-2
underfrequency
protection duration.
Specifies the level-3
overvoltage protection
threshold.
Copyright © Huawei Technologies Co., Ltd.
Unit
Value Range
V
[0.15 x Vn, 1 x Vn]
1000 V inverter:
ms
[50, 600000]
Others: [50, 7200000]
V
[0.15 x Vn, 1 x Vn]
ms
1000 V inverter:
[50, 600000]
Others: [50, 7200000]
Hz
[1 x Fn, 1.15 x Fn]
1000 V inverter:
ms
[50, 600000]
Others: [50, 7200000]
Hz
[1 x Fn, 1.15 x Fn]
ms
1000 V inverter:
[50, 600000]
Others: [50, 7200000]
Hz
[0.85 x Fn, 1 x Fn]
ms
[50, 7200000]
Hz
[0.85 x Fn, 1 x Fn]
1000 V inverter:
ms
[50, 600000]
Others: [50, 7200000]
SUN2000-65KTL-C1
V
/70KTL-C1: [1 x
Vn, 1.5 x Vn]
Others: [1 x Vn, 1.36
x Vn]
7 WebUI
Remarks
Vn represents the
rated voltage.
Vn represents the
rated voltage.
Fn represents the
rated frequency.
Fn represents the
rated frequency.
Fn represents the
rated frequency.
Fn represents the
rated frequency.
In 1000 V
inverters, only
the inverters
marked "-US"
support this
184