7. If you want to record motor data under "Optional motor data" and "Equivalent circuit diagram
data", activate the following options in the "Rating plate values" screen form:
– "Activate display of the optional motor data"
– "Activate display of the optional equivalent circuit diagram data"
The additionally activated subareas are displayed in the inspector window under "Motor
details"
8. Acquire the required motor data of the inserted motor.
Note
The input fields marked in pink
in these fields, then the device configuration cannot be completed.
Note
We recommend entering the values in the inspector window under "Motor details".
Individual parameters may be locked in the parameter view and cannot be set.
Result
The motor is specified with the manually acquired motor data. The white area turns dark gray.
If you have selected a motor with encoder, the encoder and the encoder evaluation are also
added automatically.
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2
Motor details (including additional options)
Mandatory fields (pink background)
Additional options (deactivated by default)
.
are mandatory fields. If appropriate values are not entered
Commissioning
5.3 Creating a project offline
137