Commissioning
5.3 Creating a project offline
Optional steps
You can perform the following optional steps after inserting a Hub Module:
• Close additional components connected at the Hub Module.
• Change automatically created interconnections.
• In the inspector window, change the name of the inserted Hub Module.
Assigning the DRIVE-CLiQ interfaces
If all DRIVE-CLiQ interfaces at the CU are assigned, then additional components are
automatically wired to the inserted Hub Module.
When using a CU310-2 PN, this is only applicable for supplementary system components.
5.3.9.2

Insert Communication Board CBE20

Overview
The CBE20 Communication Board is a flexible component, which can be operated in Startdrive
with the "SINAMICS link" communication profile.
Requirements
• A SINAMICS S120 Control Unit has been inserted in the device configuration.
• No Terminal Board TB30 is contained in the device configuration.
Note
A TB30 Terminal Board and a CBE20 Communication Board cannot be created simultaneously
in the device configuration.
Procedure
To insert a CBE20 into the device configuration, proceed as follows:
1. Open "Supplementary system components > Communication Boards" in the hardware
catalog.
2. Select the "CBE20 Communication Board" in the drop-down list.
3. Drag the "Communication Board CBE20" into the device view into the light gray border area
of the Control Unit.
Result
The CBE20 is inserted in the drive, and does not have to be specified in any more detail.
148
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2