Infeed Unit; Overview; Function Modules - Siemens SINAMICS S120 Commissioning Manual

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning
5.7 Basic parameterization of the drive objects
Additional functions (optional)
Function
Description
Absolute-value
Activate the absolute-value generation in the screen form if the absolute value of the scaled input value is
generation
to be generated.
The activated absolute-value generation is indicated by the
Inversion
The signal source for inverting the analog input signals can be interconnected via a BICO interconnection.
As default setting, inversion is deactivated.
If you want to make an inversion, interconnect the signal source in the "Inversion" field.
Activate
The signal source for enabling the analog input can be interconnected via a BICO interconnection.
The enable is activated as default. If required, correct the signal source here.
Analog input 0
Here, interconnect the signal sink for the input value of the analog input. Several interconnections are
possible.
Simulation mode A simulation mode can be activated in the online mode.
5.7.2

Infeed unit

5.7.2.1

Overview

Overview
Infeed units (Line Modules) include the central line infeed for the DC link. Various infeed units
are available to address various application scenarios.
Basic parameterization of the infeed unit
You define the following data in the basic parameterization of the infeed unit:

• Function modules

• Line supply data / Operating mode
• Enable logic
• Line contactor control
5.7.2.2
Function modules
Overview
When required, during the basic parameterization you can switch-in various function modules
for the selected infeed unit.
Note
You can activate or deactivate function modules only offline.
206
icon.
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2

Advertisement

Table of Contents
loading

Table of Contents