Commissioning
5.3 Creating a project offline
Procedure
To connect several Motor Modules in parallel, proceed as follows:
1. Open "Motor Modules" in the hardware catalog.
2. Drag & drop a Motor Module into the light gray area of the already existing Motor Module.
3. Specify the Motor Modules connected in parallel according to the specifications listed above.
Further information on specifying a Motor Module is provided in Chapter "Inserting and
specifying a Motor Module (Page 123)".
4. If necessary, add additional Motor Modules to the parallel connection.
Activating / deactivating individual Motor Modules
If required, you can activate or deactivate individual Motor Modules of a parallel connection
using the inspector window ("General > Project information > Component activation"). To
deactivate, the respective Motor Module must be disconnected from the line supply (using a
contactor, for example). Motor supply lines must be opened.
Further information on activating/deactivating Motor Modules in the Startdrive engineering
tool is provided in Chapter "Activating / deactivating individual drive components (Page 77)".
5.3.7

Inserting a motor

Overview
Startdrive manages the motor data of numerous motors in a motor list. As a result, motors can
be quickly specified via the inspector window. Motors that are not included in the motor list are
specified by manually entering the motor data (e.g. rating plate values) in the inspector window
(see Chapter "Inserting and specifying motors that are missing from the motor list (Page 136)").
134
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2