Commissioning
5.10 Configuring brake control
Parameterizing the "Open brake" command
To parameterize the command for the forced opening of the holding brake, proceed as follows:
1. Interconnect the "Open threshold signal source" (p1220) signal sink for the "Open brake"
command.
2. Enter the threshold for the "Open brake" command in the "Open threshold" (p1221) field.
3. Enter the monitoring time for standstill detection in the "Monitoring time" (p1227) field.
When braking with OFF1 or OFF3, standstill is detected after this time has expired, after the
set speed has fallen below p1226.
4. Interconnect the "Open brake" (p1218[0]) signal sink for conditional opening operation of
the motor holding brake and also an AND operation with input 1.
OR / AND
5. Interconnect the "Open brake" (p1218[1]) signal sink for conditional opening operation of
the motor holding brake and an AND operation with input 2.
6. Interconnect the "Unconditionally open holding brake" (p0855) signal sink for the command
to open the brake unconditionally.
The brake opens when this signal or the internal signal "Open brake" has the value "1".
Note
Prioritization of the commands
The "Unconditionally close holding brake" signal has a higher priority than the
"Unconditionally open holding brake" signal.
5.10.2.3

Closing the brake

Overview
The following describes how you can set conditions and commands for the forced closing of the
holding brake.