An unlimited number of recordings cannot be made in Startdrive for SINAMICS S120 as a result
of the restricted memory capacity:
• 2 traces can be recorded for each drive.
• A maximum of 8 signals can be recorded for each trace recording.
– 1 to 4 signals for a minimum recording cycle of 0.125 ms
– 5 to 8 signals for a minimum recording cycle of 4.0 ms
Trace configuration
The signals to be recorded, the recording time and the trigger conditions are defined in the trace
configuration.
Data storage (toolbar and curve diagram)
The trace toolbar and the curve diagram also allow the trace configuration and the analysis of
the recording to be transferred.
The data archive is schematically shown in the following diagram:
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2
Diagnostics
6.2 Diagnostics via Startdrive