3.4
User interface - One Button Tuning (OBT)
Overview
One Button Tuning (OBT) is used to determine the optimum control parameters of a servo drive.
Structure of the screen form
The following diagram shows as example the various components of the "One Button Tuning"
screen form:
①
Result of the controller optimization:
Shows among other things a comparison of the values before and after tuning.
②
Dynamic response settings
③
Activate/deactivate master control
④
Switch-on/switch-off infeed
⑤
Configuration / distance limit
⑥
Start optimization
⑦
Activate/deactivate controller optimization
⑧
Advanced settings for selected parameters
⑨
Status of controller optimization
Figure 3-10
Example: CU320-2 PN
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2
Startdrive engineering tool
3.4 User interface - One Button Tuning (OBT)
53