5.5 Alternative 1: Loading the drive configuration into the project
5.5.3

Post-processing the drive configuration

Overview
In an ideal scenario, all of the drive components are transferred into the drive configuration and
specified via the automatic configuration. In this case, the error-free configuration is confirmed
in the message display and the configuration does not have to be post-processed.
Error when reading out the drive configuration
If, however, not all drive components could be read out by the automatic configuration,
although they do exist physically, the components are created unspecified in the device view.
The missing specification must therefore be added in the device configuration.
Specifying unspecified components
To specify non-specified components, proceed as follows:
1. Click in the inner white area of the unspecified component envelope.
The area is shown as selected.
2. Open the inspector window if it has not been opened yet.
3. In the secondary navigation of the Inspector window, select "... - Selection".
A selection of the available components is displayed on the right in "... - Selection".
4. Select the component.
Result
• The component is displayed in the device view as specified (the area now has a dark color).
The data are displayed accordingly in the device overview.
• The data of the selected component unit were assigned to the unspecified component unit.