Disassembling the Reel Motor
Inspecting the Reel Motor
Hydraulic System: Service and Repairs
(Figure
84) (continued)
9. Remove and discard the back−up gaskets and pressure seals from wear
plates.
10. Turn the front flange over, with seal side up.
Make sure to not damage the front flange counter bore when
removing the seals from the front flange.
g345532
1.
Dust seal
2.
Retaining ring
11. Carefully remove the dust seal, retaining ring, backup washer and shaft seal
from the front flange
12. Remove the cross−over relief valves from rear cover if necessary.
1. Remove any nicks and burrs from all parts with emery cloth.
Use goggles or other appropriate eye protection when using
compressed air for drying parts.
2. Clean all parts with solvent. Dry all parts with compressed air.
IMPORTANT
Figure 86
3.
Backup washer
4.
Shaft seal
(Figure
86). Discard removed seals.
CAUTION
Page 5–108
Reelmaster
®
3100-D/3105-D