Tie/Did Line Type Assignment - NEC Xen IPK Programming Manual

Hide thumbs Also See for Xen IPK:
Table of Contents

Advertisement

December 2004
Tie/DID Line Type
Assignment
General Description
Use this Memory Block to assign the method of loop supervision to be used for each Trunk
associated with a Tie line.
Display
Tie/DID
No.
Data
(01~64)
No.
0 1 / 1 4 :
T I M E
Settings
LK 1
LK 2
2nd Dial
Immediate
Tone
LK 5
LK 6
Programming Procedures
Go off-line.
1
N
Press LK3 +
+
2
3
Press the corresponding CO/PBX line key to change the data option.
Note:
Use the following to enter data:
R
to go to the next CO/PBX Port No.
N
Press
to write the data.
4
P
5
Press
to go back on-line.
Related Programming
M.B. Number
3-92
Trunk (Installed, DP/DTMF) Selection
N
1. Line keys 1~4 correspond to the following methods of loop supervision:
1 = Second Dial Tone
2 = Immediate Start
3 = Delay Dial
4 = Wink Start
2. If a second dial tone is selected, the distant system provides the dial tone.
3. If Immediate, Delay, or Wink Start is selected, the local system provides the dial tone.
DRAFT 3
350 – Chapter 1
Title
I M M E D I A T E
D I S P L A Y
LK 3
LK 4
The shaded area indicates
Wink
Delayed
the default setting.
Start
LK 7
LK 8
to access the Memory Block.
AD
Memory Block Name

Tie/DID Line Type Assignment, 3-14

NEC Business Solutions Ltd
System Mode
3
Submode
Data No.
14
PC Programming
+ ALT
3-14

Advertisement

Table of Contents
loading

Table of Contents