Tie Line Answer Detect Time
Selection
General Description
Use this Memory Block to specify the duration between the time when the receiving Xen system
answers (off-hook) and the time when it is recognised as an answer.
Display
CO/PBX
No.
Data
(01~64)
No.
0 1 / 1 7 : P R E
T I M E
Settings
(Page 1)
LK 1
LK 2
0 ms.
130 ms.
LK 5
LK 6
520 ms.
650 ms.
(Page 2)
LK 1
LK 2
1040 ms.
1170 ms.
LK 5
LK 6
1560 ms.
1690 ms.
Programming Procedures
1
Go off-line.
N
2
Press LK3 +
+
3
Press the corresponding CO/PBX line key to change the data option.
Note:
The following are used when entering data:
S
to go to the next page
T
to go to the previous page
R
to go to the next CO/PBX Line No.
N
4
Press
to write the data.
P
5
Press
to go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
Answering a call may not be possible if the CO answer detect time is too long.

3-17, Tie Line Answer Detect Time Selection

Setting
Page
Title
Data
No.
3 9 0 | 1
D I S P L A Y
LK 3
260 ms.
390 ms.
LK 7
780 ms.
910 ms.
LK 3
1300 ms.
1430 ms.
LK 7
1820 ms.
1950 ms.
AG
to access the Memory Block.
LK 4
LK 8
The shaded area indicates
the default setting.
LK 4
LK 8
Programming Manual
System Mode
3
Submode
Data No.
17
PC Programming
+ ALM
DRAFT 3
Chapter 1 – 353
3-17

Advertisement