Automatic Day/Night Mode Switching Time Assignment - NEC Xen IPK Programming Manual

Hide thumbs Also See for Xen IPK:
Table of Contents

Advertisement

December 2004
Automatic Day/Night Mode
Switching Time Assignment
General Description
Use this Memory Block to assign Pattern 1 and Pattern 2 start times for automatically switching
between Day Mode and Night Mode.
Display
Pattern
Data
(1/2)
No.
2 7 : 1
T I M E
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 +
BG
3
Enter the data using the dial pad.
Note: Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
I
~
to enter numeric data
U
to clear all data when the cursor is in the Data No. position
N
4
Press
to write the data. The switching time for pattern 2 is displayed.
Use the dial pad to change the time.
5
N
Press
to write the data.
6
P
7
Press
to go back on-line.
Related Programming
M.B. Number
1-1-32
Automatic Day/Night Mode by Day of Week Selection
1-4-05
Automatic Tandem Trunk by Night Mode Selection
1-8-07
Class of Service (Attendant) Feature Selection 1
4-07
Code Restriction Class Assignment (Day Mode)
4-08
Code Restriction Class Assignment (Night Mode)
4-09
Telephone to Tenant Assignment
4-17
Station to Class of Service Feature Assignment
4-37
Extension Line Key Ring Assignment (Day Mode)
4-38
Extension Line Key Ring Assignment (Night Mode)
DRAFT 3
62 – Chapter 1
Day Mode
Night Mode
Start Time
Start Time
Setting Data
Setting Data
:
,
:
D I S P L A Y
to access the Memory Block.
Memory Block Name

Automatic Day/Night Mode Switching Time Assignment, 1-1-27

NEC Business Solutions Ltd
1-1-27
System Mode
1
Submode
1
Data No.
27
PC Programming
+ BM
Default Values
Not Specified