Call Monitoring Alert
Assignment
General Description
Use this Memory Block to specify whether or not Call Monitoring Alert Tone is allowed. When
allowed, the Conference LED indicates Call Monitoring. When denied, the Conference LED does
not indicate Call Monitoring.
System Software R2000 or higher is required.
Display
Code
Data
Table
No.
01~10
8 6 : A L E R T
T I M E
Settings
LK 1
LK 2
YS
NO
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 +
HF
3
Press the corresponding CO/PBX line key to change the data option.
N
4
Press
to write the data and display the next Memory Block.
Program the next Memory Block or press
5
Related Programming
M.B. Number
1-8-08
Class of Service (Station) Feature Selection 2 (Pg6, LK6 and LK7)
N
1. When YS is assigned, Call Monitoring Tone and the Conference LED indicate Call Monitoring.
2. When NO is assigned, Call Monitoring Tone and the Conference LED do not indicate Call Monitoring.
DRAFT 3
126 – Chapter 1
Setting Data
T O N E = Y S
D I S P L A Y
LK 3
LK 4
to access the Memory Block.
P
to go back on-line.
LK5
LK6
Memory Block Name

Call Monitoring Alert Assignment, 1-1-86

NEC Business Solutions Ltd
1-1-86
System Mode
Submode
Data No.
86
PC Programming
LK7
LK8
The shaded area indicates
the default settings.
1
1
+ AN