Ac Power Cable; Power Supply - Epson RC620 Safety And Installation

G / rs / c3 / s5 / x5 series, robot controller
Hide thumbs Also See for RC620:
Table of Contents

Advertisement

2. Installation
2.7 Power Supply / AC power Cable / Breaker

2.7.1 Power Supply

Ensure that the available power meets following specifications.
Voltage
Phase
Frequency
Momentary
Power Interrupt
Power
Consumption
Peak Current
Leakage
Current
Ground
Resistance
Install an earth leakage circuit breaker or a circuit breaker in the AC power cable
line at 15 A or less rated electric current. Both should be a two-pole disconnect
type. If you install an earth leakage circuit breaker, make sure to use an inverter
type that does not operate by induction of a 10 kHz or more leakage current. If
you install a circuit breaker, please select one that will handle the above mentioned
"peak current".
The power receptacle shall be installed near the equipment and shall be easily
accessible.
166
Item
AC 200 V to AC 240 V
Single phase
50/60 Hz
10 msec. Or less
Max. 2.5 kVA
Actual consumption depends on the model, motion, and
load of the Manipulator.
Rated consumption
= ( 150 W + total Manipulator rated consumption ) / 0.6
The rated consumption for G10 and G20 is 2.5 kVA.
Refer to Manipulator manual for Manipulator rated
consumption.
When power is turned ON : approximately 150 A (2 msec.)
When motor is ON : approximately 60 A (5 msec.)
Max. 3.5 mA
100 Ω or less
Safety and Installation (RC620 / EPSON RC+ 6.0) Rev.12
Specification

Advertisement

Table of Contents
loading

This manual is also suitable for:

G seriesRs seriesC3 seriesS seriesX5

Table of Contents