There are three types of battery connection to provide battery life in the event of a
power failure, internal battery, external battery without CHS LARGE BATT BOX and
external battery with CHS LARGE BATT BOX.
4.1
5 - 50
C
ONNECTION
Install Internal Batteries
4.1.1
Install Internal Batteries CHS1U-US Chassis
An internal battery source using two batteries can be installed using
the CHS1U BATT MTG KIT (mounting kit) and CHS1U BATT CA INT
(internal cabling).
1.
Ensure the chassis is powered down.
2.
Disconnect AC power and grounding cable from rear of
chassis.
3.
Remove screws from battery access panel on rear of chassis
(see
Figure 5-60 Removing Battery Access
Figure 5-60 Removing Battery Access Panel
4.
Remove battery access panel and set aside (refer to
5-60 Removing Battery Access
UNIVERGE SV8100/SV8300
Panel).
Figure
Panel).