Table 13-1 Ad(A)-R Unit Cable Connections - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100/SV8300
Terminal
Number
T1
T2
T3:T4
T5
T6
T7
T8
T9
System Hardware Manual

Table 13-1 AD(A)-R Unit Cable Connections

Cables to Connect
When warning tone is not being
sent from the recorder, connect wire
pair input from tone generator to
T1:T2. The warning tones from the
generator are sent to T1:T2 on a
dedicated wire pair while the
speech path is sent from the
AD(A)-R on T3:T4 over a separate
wire pair to the recorder.
Connect recorder device wire pair
speech input to T3:T4.
When the recorder used supplies a
warning tone, this tone may also be
sent over the T3:T4 wire pair back
to the terminal.
Connect the bare end of the control
cable.
Connect the shielded end of the
control cable.
Connect the bare end of the control
cable.
Unused
Terminal Specifications
Input Terminal: T1 and T2 are enabled
for tone generating device when
switches SW1-3 and SW1-4 are OFF.
When switches SW1- 3 and SW1-4 are
ON, a humming sound may be recorded
due to impedance mismatch.
Input Impedance on T1 and T2: 100K Ω
Input Level on T1 and T2: –15 dB ~ 40
dB
Input/Output Terminal:
Refer to dip switch settings in
13-2 AD(A)-R Unit Switch
When a Multiline Terminal is idle, this
contact is closed. When the Multiline
Terminal goes off-hook (using the
handset, headset, or speakerphone),
this contact is open.
When recording device owner's manual
specifies start on open circuit, connect
T5 and T6.
Provides common connection for
control cable.
When the Multiline Terminal is idle, this
contact is open. When the Multiline
Terminal is busy (using the handset,
headset, or speakerphone), this contact
is closed.
When recording device owner's manual
specifies start on closed circuit, connect
T6 and T7.
Issue 1.0
Table
Settings.
13 - 9