5. Diagnosis Screens
Display items
Display item
(1) Software list
(2) NC serial No.
(3) Hardware list
(to the next page)
Display item
(from the previous
page)
Menus
Menu
This displays the software list.
S/W
config
This displays the hardware list.
H/W
config
This displays the PLC program list (file name, file label, and execution
Ladder
type
config
This displays a list of the software being used.
This displays the NC model name, serial No, model type, and unit type.
NC TYPE:
MITSUBISHI CNC 75XL
MODEL NAME:
FCA730
SERIAL NO.:
M7123456789
UNIT NAME:
FCU7-MU011
This displays each hardware name.
CNC
: HN115A
: HN081A
: HN122A
: HN48xA
ATT CARD
: HN392A
EXT
: EX891
: HR553
: HR577
RI01 [n]
:
RI02 [n]
:
RI03 [n]
:
Details
5.1 System Configuration Screen
Details
NC type
(The model names include 730M, 735M, 750L and 755L.)
Model name
(The model names include FCA720, FCA730 and FCA750.)
Serial No.
Unit type
(The unit type differs according to the model.)
Main card with LANCPU
Power card
CPU card (Differs between M720, M730, M750)
Memory card
(Differs between M720, M730, M750 (hardware option))
The CNC unit is composed of four PCBs. Bus connections are
used with all cards.
Card enclosed with CNC card. The operation board I/O unit
are connected to it.
The operation board I/O unit uses a remote IO connection.
Back panel
Extension unit
Extension unit
The extension unit is a hardware option. The PLC high-speed
engine or PROFIBUS card, etc. is connected.
The back panel + up to three cards are displayed.
Details
Remote IO unit 1 (n = 1 to 8)
Remote IO unit 2 (n = 1 to 8)
Remote IO unit 3 (n = 1 to 6)
There are up to three channels. The 7th and 8th station of the
RIO3 channel is fixed for use with the handle I/F and is not
displayed.
210