2. Monitor Screens
Operation method (Registering the verify stop)
(1) Select the part system for executing verify
stop with the
$<->$
(2) Press the main menu
(3) Select the device.
(Example)
(4) Using the
↑ ,
keys, move the cursor to the directory
containing the file to be set.
If the list contents differ from the actual device or directory, press the menu List update .
(5) Press the
INPUT key.
(6) Input the program No., sequence No. and
block No. using / as a delimiter.
(Example) 1001/1/2
When carrying out verify stop of and MDI
program, set "0" as the program No.
If pointing the cursor to a file name, the file
name is echoed back to the input area.
(7) Start the automatic operation.
key.
Verify stop .
HD
↓ ,
and
INPUT
The currently selected part system is displayed at the upper
left of the screen.
The verify stop submenu appears.
The list appears as a pop-up window.
The device name and root directory (HD:/) selected in the
device name and directory display fields are displayed.
The following is displayed.
The cursor moves within the directory.
The verify stop position is displayed, and the program No.
("MDI" for MDI mode), sequence No., block No. and
[Verifying] appear.
When the verify stop is completed, a message
indicating the end appears.
The stop position displayed on the screen is cleared, and the
[Verifying] display is erased.
78