Hitachi GR2000 Series Configuration Commands page 399

Hitachi gigabit router configuration guide
Hide thumbs Also See for GR2000 Series:
Table of Contents

Advertisement

Table 5-3
Invalid phone number.
Invalid physical interface type.
Invalid remote IP address.
Invalid remote IP address.
Invalid timeslot number.
Invalid traffic.
IP address configuration not specified.
IP configuration not specified.
Line already defined.
LINE No. out of range.
Links not specified.
Max packet size is greater than max packet
size (Frame Relay).
Max packet size is less than dlci max packet
size(dlci).
Maximum number of DLCI configurations are
already defined.
Maximum number of ethernet line are already
defined.
Maximum number of Frame Relay
configurations are already defined.
Maximum number of isdn_ppp configurations
are already defined.
Maximum number of NIF are already defined. No line settings are possible. Recheck the number of lines per RP.
Maximum number of PPP configurations are
already defined.
Maximum number of pppoe configurations are
already defined.
Maximum number of traffic are already
defined.
Maximum number of traffic ubr are already
defined.
Maximum number of TUNNEL configurations
are already defined.
Maximum number of vc are already defined.
Maximum number of vc configurations are
already defined.
GR2K-GA-0014
Ver. 07-02
Network Interface Error Messages (continued)
Invalid phone number. Set own telephone number in the line that set
own telephone number to the same.
The interface type of the backup server is illegal. The Ethernet or
frame relay may not be designated.
The remote IP address is illegal. If the local IP address is IPV4, set
the remote IP address to IPV4. Or, if the local IP address is IPV6, set
the remote IP address to IPV6.
The remote IP address is illegal. Set the correct remote IP address.
Or use different IP addresses for the local and remote servers.
Or, the IPV6 local address and the IPV6 remote address are not in
the same scope.
In the J2 timeslot:
Although channel width is 24 or less, it exceeds the range of 96
timeslots and quartered 24 timeslots.
--> Although the channel width exceeds 24, it is not 1, 25, or 49.
Specify the value so the timeslot number and timeslot specified in
channel width are within the 24 timeslots defined by quartering 96
timeslots.
--> Specify 1, 25, or 49 in the timeslot number.
Traffic invalid. Set a correct traffic.
IP address configuration not specified. Set IP address.
IP routing has not been specified. Specify IP routing.
A line is already defined. Define the line in another line number.
Specified line number exceeds maximum value. Check the line
number.
Links not specified. Set overload link count.
Field maximum value is greater than the Frame Relay field maximum
value. Specify the value so the field maximum value is no greater
than the Frame Relay maximum value.
Field maximum value is less than some DLCI field maximum values.
Correct DLCI field maximum values so they are more than all DLCI
field maximum values of this line.
No more DLCI configurations can be defined. Check the network
configuration.
No more Ethernet lines can be added. Check the network
configuration.
No more Frame Relay configurations can be set. Check the network
configurations.
No more isdn_ppp configurations can be set. Check the network
configuration.
No more PPP configurations can be set. Check the network
configurations.
No more PPPoE configurations can be set. Check the network
configurations.
256 types of traffic per line are already set. Check the network
configuration.
Maximum number of traffic ubr are already defined. Check the
network configuration.
No more TUNNEL configurations can be set. Check the network
configurations.
2048 vc per line are already defined. Check the network
configuration.
Maximum number of vc configurations are already defined.
Check the network configuration.
Configuration Error Messages
5-9

Advertisement

Table of Contents
loading