Table 5-8
lower out of range
Masklen is not in range of 0 to 32.
max_rate is not in range of 0 to 2400000.
max_rate_burst is not in range of 0 to 131072. The input value is out of the prescribed range. Set the range of 0 to
Maximum number of Flow IPv6
Filter_interface configurations are already
defined.
Maximum number of Flow IPv6 Filter_list
configurations are already defined in one Flow
Filter_inteface configuration.
Maximum number of Flow IPv6 Filter_list
configurations are already defined.
Maximum number of Qos/Filter IP Flow
configurations are already defined.
min_rate is not in range of 0 to 2400000.
min_rate or max_rate not specified.
min_rate_burst is not in range of 0 to 131072. The input value is out of the prescribed range. Set the range of 0 to
No enough parameters.
no such flow
No such flow filter list No.
No such flow qos list No.
penalty_discard out of range
penalty_tos out of range
Policy interface name can not set at
rmEthernet.
Policy interface name not found at
[<Interface_Name>]
Policy_group name not found at
[<Policy_Group_Name>].
port_destination out of range
port_source out of range
precedence out of range
prefixlen out of range
priority out of range
GR2K-GA-0014
Ver. 07-02
Flow Information Error Messages (continued)
The input value is outside the specified range. Set the lower limit of
IP user data length in the range of 0 to 65535.
The input value is outside the specified range. Set the mask length in
the range of 0 to 32.
The input value is outside the specified range. Set the maximum
band restriction in the range of 0 to 2400000.
131072 to the maximum band limitation burst size.
The number of entries in an interface, including a flow IPv6 filter list,
which can be set per router exceeds the range. Set the interface,
including a flow IPv6 filter list, to within 128 entries per router.
The number of entries in a flow IPv6 filter that can be set per
interface exceeds the range. Set the flow IPv6 filter to within 16
entries per interface.
The number of entry for the flow IPv6 filter that can be set per device
has exceeded the range.
The number of entries in a flow QoS/Filter that can be set per
interface or router, exceeds the range. Set the flow QoS/Filter to
within 2000 entries per RP or 10000 entries per router.
The input value is out of the prescribed range. Set the range of 0 to
2400000 to the minimum band guarantee.
The detection conditions of an important packet flow are set, but the
maximum band limitation or minimum band guarantee is not set. Set
the maximum band limitation or minimum band guarantee.
131072 to the minimum band guarantee burst size.
Parameters are insufficient. Specify the necessary parameters.
Applicable flow configuration definition does not exist.
The specified list number does not exist because the action of a flow
filter was changed. Specify the previously set list number when
action was changed.
The specified list number does not exist because the action of a flow
qos was changed. Specify the previously set list number when action
was changed.
The input value is out of the prescribed range. Set the range of 1 to 4
to delete contract band breaching queuing priority.
The input value is out of the prescribed range. Set the range of 0 to
255 to delete contract band breaching tos rewrite value.
The interface for the policy routing cannot be set in the interface of
mEthernet. Set other interface name.
The interface specified in the policy routing cannot be found. Set the
interface name.
The specified in the policy group cannot be found. Set either the
policy routing or the policy group set in the policy routing.
The input value is out of the prescribed range. Set the range of 1 to
65535 to the destination port number.
The input value is out of the prescribed range. Set the range of 1 to
65535 to the source port number.
The input value is out of the prescribed range. Set the range of 0 to 7
to the precedence value.
The input value is out of the prescribed range. Set the range of 0 to
128 to the prefix length.
The input value is out of the prescribed range. Set the range of 1 to
1000 to the output priority.
Configuration Error Messages