Selecting a Camera
Select a camera image to set "Flaw Detection".
1.
Select "Area Setting" in "Flaw Detection"
setting window.
2.
Select a camera No. in "Camera".
The selected camera image is displayed.
Select a displayed image type (Live/Memory and Gray/Binary) or magnification in "Image Menu" opened
by pressing the F1 key.
Selecting Preprocess / Position Adjustment
page 95
Setting an Inspection Area
Set a range to detect a flaw.
1.
Select "Area Setting" in "Flaw Detection" setting window.
2.
Select "Area (Set)".
"Area Setting" window is displayed.
3.
Select a shape of inspection area from "Change Shape".
Select from Line, Plane, and Ellipse.
4.
Select "Change" and draw an area.
The setting procedure differs depending on the shape in Flaw Detection.
5.
After drawing is completed, press the CANCEL key.
Using Area Size Adjustment
Area Size Adjustment is a function for inspecting variable-sized objects. The function adjusts an inspection
area according to the size of the object detected with Area Size Adjustment checker.
Refer to Chapter 4.9, page 208 about Area Size Adjustment and the setting procedure.