About Graphs and Cell results to be displayed
Measurement values of each cell obtained from test results are displayed as graphs in Smart Edge (Line). The
graph shows the status of edge detection for each cell or whether they are within edge threshold as marks.
It is also possible to show a list of the status of edge detection or detection data for all cells.
About Graphs
(1)
Graph type:
(2)
Maximum:
(3)
Minimum:
(4)
Horizontal axis:
(5)
Result of each cell:
It shows a graph of deviation data when Detect Mode is "Measure Deviation". It
shows a graph of distance data when selecting "Measure Distance", and a graph
of width data when selecting "Measure Width". When threshold has been set in
Edge Detect Condition, a graph of differential is shown.
However, a graph of deviation is shown regardless of the set detect mode when
setting "Edge Detect Condition" or setting "Judgement Limits" > "Denoising".
The maximum and minimum values of measurements. This is the value of
measurement (deviation, distance, width) that is calculated based on the
coordinate of edge detected by each cell before applying various parameters such
as Judgement Limits. It may be different from the maximum measurement or
minimum measurement displayed at the bottom of the screen. (Because the data
displayed at the bottom of the screen is the value after applying the denoising
function.)
Cell No. (Max. 3000)
It shows detected positions of each cell. It also shows detection results or
maximum and minimum measurement values as marks.
Mark
Color
Description
●
Yellow
Min. Measurement
green
●
Green
Max. Measurement
×
Red
Edge: Undetected
×
Blue
Excluded edge by
denoising
◆
Light
Judgment: OK
blue
◆
Red
Judgement: NG
Cell result list (*)
Display of judgement field
OK/NG
OK/NG
Undetected
Excluded
OK
NG
*)Next page
189