4.4 Inspecting Divided Type (Execution Mode)

In PV500, checkers can be divided by checker number to execute just one checker, multiple checkers or all
checkers. Divided part is "Block" and the mode to decide how to execute is "Execution mode".
Checkers are divided in 100-block-unit from checker No.0. The maximum
block number is 10.
If you set the number of blocks to "2", for example, checker No.0 to 99 are
sorted in block No.0, checker No.100 to 199 are in block No.1 respectively. In
this case, after checker No.199 cannot be set.
Although checkers No.0 to 999 can be selected if you set the number of blocks to "10", not all checkers can be
always created because the memory capacity of PV500 is constant regardless of the number of blocks.

4.4.1 Selecting an Execution Mode

Select an execution mode according to the inspection to perform. Specify an execution mode from "TYPE" >
"Type Setting".
Usage
To execute inspection using only one product type.
To use many product types when there is enough time to switch the
product types.
To execute inspections of many parts in a captured image at a time.
To use many checkers, numerical calculations and judgement expressions
to perform complicated calculations in an inspection.
To execute different inspection items, checkers or conditions, depending
on the type and status of target.
Example 1:
To determine if the object is reversed or not and inspect with the proper
conditions for each status.
Example 2:
To identify the type at an assembly line
where multiple types of objects are
running down at a time and inspect with
the proper condition for each type.
To execute various types of simple inspections
Example:
Only a few checkers are used for each product type, but more than 256
product types exist.
To save time to switch product types
Example:
To execute inspections speedily, switching multiple types (up to 10) of
conditions.
Type 0
74
Type 0
Block
Checker
(Up to 10)
(Up to 1000)
No.0
No.0 - 99
No.1
No.100 - 199
:
No.9
No.900 - 999
Execution Mode
"Execute
All"
Executes all Checkers,
Numeric Calculations
and Judgements in a
product type.
"Automatic
Switch"
Executes multiple
inspections effectively.
"User
Defined"
Executes some of the
inspections in a
product type.
(Specify before
executing inspection.)