Setting Delay Time from START Signal Input to
Image Capture
Specify the time after inputting START
0-3 signals before cameras start
capturing. Default value is "0". After
signal input, the camera starts image
capture without delay. Use it as
necessary.
This setting can be set individually for
each camera.
1.
Select the camera No. to set in "Camera" window.
2.
Select "Capture Delay".
3.
Specify the time from START signal input to capture start.
Settable range: 0.0 to 999.9 ms
Setting FLASH Delay and Pulse Output Width
After inputting START 0-3 signals, light emission timing signal is output from FLASH 0-3 of I/O connector to
external strobe flash in pulse. Specify output delay of FLASH signal and outputting pulse width.
1.
Select the camera No. to set in "Camera" window.
2.
Select "FLASH Delay" and specify delay time.
Settable range: 0.0 to 999.9 ms
3.
Select "FLASH Span" and specify pulse width of FLASH signal.
Settable range: 0.2 to 999.9 ms
The lighting is needed to be lit while the camera is capturing an image. Set them correctly along with
Capture delay of the camera and Shutter speed.
FLASH signal timing chart: Page 387.