FX-2N series by Mitsubishi Electric Corporation
·
CPU: FX2N, FX3U, FX3UC
Communication adapter: FX2N-232-BD, FX3U-232-BD, FX3U-232-ADP
·
Protocol: Special protocol for FX2N
Register for specifying communication format: Store "0" in D8120. (Reboot the PLC after the setting.)
·
Usable device
Data output/ Type switch
Data output completion notice
·
Sum check: Yes
With PLC, you cannot select to perform sum check. Automatically "Yes" is selected.
C, CV, and CS1 series by OMRON Corporation
·
Protocol: Host link
·
Usable device
Data output/ Type switch
Data output completion notice
·
Make the following setting with PLC.
-
Sum check: Yes
-
Station No.: "0"
·
Communication is not available when PLC is in "Run" mode. Change to "Monitor" mode to communicate.
SLC series by Allen-Bradley
·
Usable device
Data output/ Type switch
Data output completion notice
·
Make the following setting with PLC.
-
Duplicate Detect: OFF
-
ACK Timeout (*20 ms): 20
-
Control Line: NO HANDSHAKING
-
Error Detect: CRC
-
NAK Retries: 3
-
ENQ Retries: 0
-
Embedded Responses: AUTO DETECT
MICREX-SX (SPH series) by Fuji Electric FA Components &
Systems Co., Ltd.
·
Usable device
Data output/ Type switch
Data output completion notice
·
Sum check: Yes (type: BCC, the calculation method developed by Fuji is used.)
D
Register*
M
Bit
Invalid
D / DM
Register*
CIO / IR
Bit
0-15 (0-F)
N7 (Only integer registers)
Register*
N7
Bit
0-15 (0-F)
%MW3
Register*
%MW3
Bit
0-15 (0-F)
(Usable Range: 0 to 9999)
(Usable Range: 0 to 999)
(Usable Range: 0 to 254,
only integer registers)
(Usable Range: 0 to 15360)
419