Output format of Judgement data:
Output Data
Number of Data
Values to be Output
Output format of Total Judgement:
Output Data
Number of Data
Values to be Output
Output format of Scan Count and Numerical Calculation:
The values that can be output are only integers. Actual values with value after decimal point are rounded to
whole number and output.
Output Data
Number of Data
Values to be Output
A Judgement is output in 4-bit (digit) unit
Four data of Judgement per word from PLC are saved starting with LSB.
When the outputting data is other than multiples of four, hexadecimal E is
output.
Up to 1000
OK
1 in hexadecimal form (0001 in binary form)
NG
0 in hexadecimal form (0000 in binary form)
Error
E in hexadecimal form (1110 in binary form)
Unset
Data are not output. (But if the Judgement data Nos. before and
after the unset data No. are set to output, E is output in 16-digit
form (1110 in binary form).)
Regardless of output bit width, it is output in the last bit using one word.
1
OK
1 in hexadecimal form (0001 in binary form)
NG
0 in hexadecimal form (0000 in binary form)
Error
E in hexadecimal form (1110 in binary form)
Unset
E in hexadecimal form (1110 in binary form)
Differs depending on the setting of Output bit width.
Range of 16-bit: -32768 to 32767
Range of 32-bit: -2147483648 to 2147483647
Numerical Calculation: Up to 1000
Normal
Overflow (when exceeding the
specified "Bit Width")
Error
Unset
Calculation results:
-2147483648 to +2147483647
0
(including the overflowing numeric
calculations and the results)
0
Data are not output.
421