Inspection start
When using common trigger in "Execute All" or "Automatic
Switch" execution mode
% S
Send
Receive
% S
Error (ERROR 0 signal = ON)
% S
Error code
160
200
201
202
203
When using common trigger in "User-Defined" execution
mode
% S ?
Send
Receive
% S
Error (ERROR 0 signal = ON)
% S
Error code
160
200
201
202
203
Example:
Starts the inspection of block No.2.
Send
Receive
398
BCC
CR
$
BCC(52)
CR
!
Error code (3-digit)
Position adjustment for a detect trigger is unset or a base position is unset
when "Camera Trigger" is set to "Detect Trigger (common)".
Operation is stopped.
"Camera Trigger" in "Camera" is set to "Individual".
Execution mode is "User-Defined".
No camera is connected.
BCC
CR
$
BCC(52)
CR
!
Error code (3-digit)
Position adjustment for a detect trigger is unset or a base position is unset
when "Camera Trigger" is set to "Detect Trigger (common)".
Operation is stopped
Execution mode is NOT "User-Defined" in PV500.
"Camera Trigger" in "Camera" is set to "Individual".
The specified block is invalid (the number which does not/ cannot exist was
specified)
No camera is connected.
The specified camera number is set to "Unused" in PV500.
% S
2
*
* CR
% S
$
5
2 CR
BCC = 76 or **
BCC
CR
? = 0 - 9 (Block No. to execute)
BCC
CR