8.2.2 I/O Terminal Block

All input signals are also available for I/O connector. Use one of I/O connector and I/O terminal block.
Connecting to the both terminals might damage PV.
The input/output circuit is the same as the I/O connector. See page 364.
Pin Arrangement
Input
No.
Signal (indication)
1
COMMON (COM)
2
START 0 (STA0)
3
COMMON (COM)
4
TYPE (TYPE)
5
DISPLAY (DISP)
6
ASSIGN 0 (ASN0)
7
ASSIGN 1 (ASN1)
8
ASSIGN 2 (ASN2)
9
IN 0
10
IN 1
11
IN 2
12
IN 3
13
IN 4
14
IN 5
15
IN 6
16
IN 7
366
Description
Common for input
Image capture with
Camera 0
Common for input
Type Switch
Layout Switch
Function assignment
0-2
(select from 15
functions)
Input data 0-7
Output
No.
Signal (indication)
1
COMMON (COM)
2
READ END 0
(REN0)
3
READY0 (REDY)
4
ERROR 0 (ERR0)
5
ACCEPT (ACPT)
6
ERROR 1 (ERR1)
7
RESULT (RSLT)
8
TACT
9
OUT 0
10
OUT 1
11
OUT 2
12
OUT 3
13
OUT 4
14
OUT 5
15
OUT 6
16
OUT 7
Description
Common for output
Image capture with
Camera 0 complete
Ready completion signal
Error signal 0
Signal* acceptance
(*Type, Display, Reentry,
Assign, Run/Stop)
Error signal 1
Total Judgement
Reading timing of
inspection data
Output data 0-7