Output
No.
Signal
1
COMMON
FLASH 0 designated common
3
COMMON
FLASH 1 designated common
5
COMMON
FLASH 2 designated common
7
COMMON
FLASH 3 designated common
9
READ END 0
Image capture with Camera 0
complete
11
READ END 2
Image capture with Camera 2
complete
13
READY
Ready completion signal
15
ACCEPT
Signal of acceptance the next
signal
17
RESULT
Total Judgement
19
STROB
Data output complete
21
OUT 0
Output data 0-15
23
OUT 2
25
OUT 4
27
OUT 6
29
OUT 8
31
OUT 10
33
OUT 12
35
OUT 14
37
COMMON
Common for output
39
NC*
Unconnected
*NC = No connection
The output commons (No.37, 38) are for No.9 to 36. When you use Flash signals (Flash 0-3), connect with
respective designated commons (Pin No.1, 3, 5, 7).
*1: It cannot be accepted when ReadEnd signal is Off.
*2: Excepting when assigning function of "Abort Inspection/Process".
362
TYPE
DISPLAY
REENTRY*1
ASSIGN*2
No.
Signal
2
FLASH 0
Flash signal for Camera 0
4
FLASH 1
Flash signal for Camera 1
6
FLASH 2
Flash signal for Camera 2
8
FLASH 3
Flash signal for Camera 3
10
READ END 1
Image capture with
Camera 1 complete
12
READ END 3
Image capture with
Camera 3 complete
14
ERROR 0
Error signal 0
16
ERROR 1
Error signal 1
18
TACT
Inspection data read timing
20
RUN
Running status (On when
running)
22
OUT 1
Output data 0-15
24
OUT 3
26
OUT 5
28
OUT 7
30
OUT 9
32
OUT 11
34
OUT 13
36
OUT 15
38
COMMON
Common for output
40
NC*
Unconnected

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pv500v2

Table of Contents