Selecting a Camera
Select a camera image to set a checker.
1.
Select "Area Setting".
2.
Select a camera No. in "Camera".
The selected camera image is displayed.
Select a displayed image type (Live/Memory or Gray/Binary) or magnification in "Image Menu" opened by
pressing the F1 key.
Selecting Preprocess / Slice Level / Position
Adjustment
page 95
Setting Inspection Area
You cannot set a Mask Area.
1.
Select "Area Setting".
2.
Select "Set" of "Area Setting".
"Area Setting" window is displayed.
3.
Move the area to inspecting area by operating
the ENTER key and press the ENTER key to fix
the position.
4.
Move the start point and fix it. Then, move the
end point and fix it.
5.
Set the size (W) of cells which inspect
appearance for each pin.
Set a cell for a pin.
The widths in X and Y directions of a cell are
defined in accordance with the position of start point
and end point as the figures shown on the right.
6.
Tilt the ENTER key left/right to specify the
number of cells (N), and press the ENTER key to
fix it.
Set the number of cells to the same number as of
pins.
X
(ENTER key,
left/right)
ST
X coordinate of
the start point
ED
X coordinate of
the end point
W
Width-X of cell
N
Number of cells
(Max. 100)
Y
(ENTER key,
up/down)
Y coordinate of
the start point
Y coordinate of
the end point
Width-Y of cell