Item
Checker - Connector Gray
Window (CGW) No.0-999
Checker - Connector Gray
Edge (CGE) No.0-999
Smart Edge (Circle) (SEC)
No.0-999
Smart Edge (Line) (SEL)
No.0-999
Geometry Calculation
(GGC) No.0-999
*1) Measurement Value = Radius, Diameter or Width (decided according to the setting value of Detect Mode)
*2) Measurement Value = Deviation, Distance or Width (decided according to the setting value of Detect Mode)
Judgement (JUDGE)
Individual
Judgement(PJUDGE) No.0-99
Judgement (JUDGE)
Pitch total judgement
(PTJUDG)
Distance Difference Total
Judgement (UTJUDG)
Pitch Judgement(PJUDGE)
No.0-99
(Judgement of each pitch)
Distance Difference
Judgement(UJUDGE) No.0-99
(Judgement of each distance
difference)
Judgement (JUDGE)
Measurement Judgement
(LJUDGE)
Standard Devation Judgement
(SJUDGE)
Circularity Judgement
(CJUDGE)
Unused Edge Count
Judgement (FJUDGE)
Individual Judgement
(IJUDGE) No.0-3599
Judgement (JUDGE)
Measurement Judgement
(LJUDGE)
Standard Devation Judgement
(SJUDGE)
Linearity Judgement (JUDGE)
Unused Edge Count
Judgement (FJUDGE)
Individual Judgement
(IJUDGE) No.0-3599
Judgement (JUDGE)
X Judgement (XJUDGE)
Y Judgement (YJUDGE)
Standard Deviation
Judgement (SJUDGE)
Angle Judgement (AJUDGE)
Distance Judgement
(DJUDGE)
Condition for OK judgement
Pitch Total Judgement and Distance Difference
Total Judgement are both OK.
Pitch Judgements are all OK.
Distance Difference Judgements are all OK.
The detected pitches are within the Judgement
limits of pitches.
The detected distance difference is within the
Judgement limits of distance difference.
The judgements of Measurement Value, Standard
Deviation, Circularity and Unused Edge Count are
all OK.
Measurement Value*1) is within the range of the
maximum/minimum limitations.
Standard Deviation is within the range of the
maximum/minimum limitations.
Circularity is within the range of the
maximum/minimum limitations.
Unused Edge Count is within the range of the
maximum/minimum limitations.
The result of the cell with the specified No. is OK.
(Undetected, excluded and NG cells are NG.)
The judgements of Measurement Value, Standard
Deviation, Linearity and Unused Edge Count are
all OK.
Measurement Value*2) is within the range of the
maximum/minimum limitations.
Standard Deviation is within the range of the
maximum/minimum limitations.
Linearity is within the range of the
maximum/minimum limitations.
Unused Edge Count is within the range of the
maximum/minimum limitations.
The result of the cell with the specified No. is OK.
(Undetected, excluded and NG cells are NG.)
All the judgements for the items set in Judgement
Limits are OK.
IP X or Center X is within the range of the
maximum/minimum limitations.
IP Y or Center Y is within the range of the
maximum/minimum limitations.
Standard Deviation is within the range of the
maximum/minimum limitations.
Line Angle is within the range of the
maximum/minimum limitations.
Distance is within the range of the
maximum/minimum limitations.