Restrictions on when waiting for Individual Trigger
Note the following restrictions on when waiting for Individual Trigger (at the time of "To" in the above figure)
without using the timeout function.
"Type Switch" and "Read Setting Data" with signals from the external device
Type Switch or Read Setting Data will be executed if the signal of Abort Inspection/Process or the signal of the
rest of Image Capture is input within 10 seconds from input of Type Switch signal or Read Setting Data signal. If
10 seconds passed, Type Switch or Read Setting Data will be canceled and ERROR 1 signal will be output.
When Individual Trigger Timeout function is employed, Type Switch or Read Setting Data will be executed after
the period of the Timeout passed.
Type Switch with the keypad in RUN Menu
If the signal of the rest of image capture is
input within 10 seconds from the execution
of Type Switch, the type will be switched at
the time. If the signal of image capture is
not input after 10 seconds passed, the
message on the right appears.
Yes:
No:
Not select:
(Keep displaying the
message)
Switching to RUN Menu form SETUP Menu
Switching to RUN Menu from SETUP
Menu displays the message on the right.
(*1)
If the signal of the rest of image capture is
input within 10 seconds after selecting
"Yes", the screen will be switched to RUN
Menu at the time.
If the signal of image capture is not input
after 10 seconds passed, the message on
the right appears.
Yes:
No:
Not select:
(Keep displaying
the message)
*1) Only when changing the setting in SETUP Menu.
62
Discards the images already captured, cancels Individual Trigger, and switches Type.
The status will be the one to start an inspection again from the beginning.
Cancels the operation of Switch Type, and returns to the state of waiting for
Individual Trigger.
The state will be the one of waiting for Individual Trigger displaying the message. If the
signal of the rest of image capture is input, the type will be automatically switched.
Discards the images already captured, cancels Individual Trigger, and switches to RUN
Menu. The status will be the one to start an inspection again from the beginning.
The state will be the one of waiting for Individual Trigger in SETUP Menu.
The state will be the one of waiting for Individual Trigger displaying the message in
SETUP Menu. If the signal of the rest of image capture is input, the screen will be
automatically switched to RUN Menu.
Execute Type Switch.
After 10 seconds
After 10 seconds