5
To disable a button
In the Panel >Xpt Assign >Table Button Assign menu, select the button you
want to disable, and press [Inhibit].
To delete any currently assigned signal
In the Panel >Xpt Assign >Table Button Assign menu, select the button
corresponding to the signal you want to delete, and press [Delete] in the
<Button Assign> group.
The signal assigned to the button number next to the selected button number
and following signals move up one line.
Note
When a button number in the range 121 to 128 is selected, execution of
"Delete" is impossible. The signal assignments to button numbers 121 to 128
cannot be changed. When a signal assigned to any other button number is
deleted, moving up of signals ends when the signal assigned to number 120 has
moved to number 119, and the signals assigned to numbers 121 to 128 are
maintained in their original lines.
To return the table to its default state
1
324
Setup Relating to Operations From the Control Panel
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
Parameter
Adjustment
3
V/K Pair No
Selection of video and key pair
number to be assigned
Using the buttons in the <Button Assign> group, assign the selected pair
number to the button number currently selected in table 1.
Set: Delete the signal currently assigned to the selected button number and
make a new assignment.
Insert: Move down one line the signal currently assigned to the selected
button number and following signals, and make a new assignment.
Note
When a button number in the range 121 to 128 is selected, execution of
"Insert" is impossible. The signal assignments to button numbers 121 to
128 cannot be changed. When "Insert" is executed for any other number,
moving down of signals ends at number 120, and the signals assigned to
numbers 121 to 128 are maintained in their original lines.
In the Panel >Xpt Assign >Main, V/K Pair Assign menu or Panel >Xpt
Assign >Table Button Assign menu, press [Default Recall].
Setting values
1 to 128