Setup Relating to Switcher Processor
Settings for Switcher Configuration (Config Menu)
To make settings for the switcher processor configuration, use the Switcher
>Config menu.
To display the Config menu
In the Engineering Setup menu, select VF3 'Switcher' and HF1 'Config.'
The status area shows the output signal assignment for each of the M/E and
PGM/PST banks.
Adjusting the reference phase
To adjust the switcher internal reference phase, in the Switcher >Config menu,
set the following parameter.
Knob
3
Specifying the video switching timing
1
In the Switcher >Config menu, press [Switching Timing].
The Switching Timing menu appears.
2
Select any of the following.
Any: Not specified
Field 1: Field 1 (odd fields)
Field 2: Field 2 (even fields)
Setting the operation mode
In the <M/E Config> group of the Switcher >Config menu, select the operation
mode for each M/E or P/P bank from the following.
• Standard mode
• Multi Program mode
• DSK mode (P/P only)
For details of the modes, see "Switcher Setup" in Chapter 1 (Volume 1).
Parameter
Adjustment
Phase
Switcher internal reference phase
Setting values
–32.00 to +96.00
Setup Relating to Switcher Processor
361