Sony DVS-9000 User Manual page 349

Production switcher system
Hide thumbs Also See for DVS-9000:
Table of Contents

Advertisement

2
3
Making control panel GPI output settings
1
2
3
4
348
Setup Relating to Operations From the Control Panel
Using any of the following methods, select the settings.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob Parameter
1
No
To apply the selection made in step 2 when the input is the GPI high level,
press [H Set]. To apply the selection made in step 2 when the input is low,
press [L Set].
This confirms the setting, which appears in the status area.
In the Panel >Device Interface menu, press [GPI Output].
The GPI Output menu appears.
Using any of the following methods, select the settings.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob Parameter
1
Port
In the <Trigger Type> group, select the trigger polarity.
(Rising Edge): The trigger causes the relay contacts to be open-
circuit or drives the output high, and holds this state for the
specified pulse width.
(Falling Edge): The trigger causes the relay contacts to be shorted
or drives the output low, and holds this state for the specified
pulse width.
(Any Edge): Each time the trigger occurs, the relay contacts are
alternately closed or opened, or the output is switched between
high and low.
Status: Depending on the status, the relay contacts are closed or opened,
or the output is switched between high and low.
No Operation: The trigger has no effect on the relay state or output level.
Turning the knobs, select the pulse width and timing to be set.
Adjustment
Signal format/screen
aspect ratio selection
Adjustment
Port selection
Setting values
1 and upwards
Setting values
1 to 8