2
Adjust the following parameters.
Knob
2
3
4
To set the values to the default values, press [Default].
Making vertical blanking interval adjustment and through mode
settings
1
In the Switcher >Output menu, press [V Blank/Through].
The V Blank/Through menu appears.
The status area shows the output ports and the assigned signals, the vertical
blanking interval, and the through mode Enable/Disable status.
2
Press [V Blank Mask].
3
Adjust the parameter.
Knob
2
a) Depending on the signal format, the adjustment range varies as follows.
• 480i: 10 to 19
• 576i: 6 to 22
To return the values to their defaults, press [Default].
4
To enable the through mode, press [Through Mode], setting it to Enable.
The through mode can be applied to the following outputs.
• Aux 1 to 48 outputs
• Program outputs of the M/E and PGM/PST rows
• Clean outputs of the M/E and PGM/PST rows
Making safe title settings
1
In the Switcher >Output menu, press [Safe Title].
The Safe Title menu appears.
Parameter
Adjustment
White Clip
Luminance signal white clip value 90.00 to 109.02
Dark Clip
Luminance signal dark clip value
Chroma Clip Chrominance signal clip value
Parameter
Adjustment
Mask End
Final value for vertical blanking
interval
Setting values
–6.85 to +10.00
90.00 to 113.17
Setting values
See note a) below
Setup Relating to Switcher Processor
369