Function
Pr.
Pr.
group
Basic functions
0
G000
1
H400
2
H401
3
G001
4
D301
5
D302
6
D303
7
F010
8
F011
9
H000
C103
DC injection
10
G100
brake
11
G101
12
G110
13
F102
14
G003
Jog operation
15
D200
16
F002
17
T720
18
H402
19
G002
Acceleration/
20
F000
deceleration
times
21
F001
Stall prevention
22
H500
23
H610
Multi-speed
24 to
D304
setting
27
to
D307
Name
0 to 30%
Simple
Simple
Simple
Torque boost
Maximum frequency
0 to 120 Hz
Simple
Simple
Simple
Minimum frequency
0 to 120 Hz
Simple
Simple
Simple
0 to 590 Hz
Simple
Simple
Simple
Base frequency
Multi-speed setting (high
0 to 590 Hz
Simple
Simple
Simple
speed)
Multi-speed setting
0 to 590 Hz
Simple
Simple
Simple
(middle speed)
Multi-speed setting (low
0 to 590 Hz
Simple
Simple
Simple
speed)
Acceleration time
0 to 3600 s
Simple
Simple
Simple
Deceleration time
0 to 3600 s
Simple
Simple
Simple
Electronic thermal O/L
0 to 500 A
Simple
Simple
Simple
relay
0 to 3600 A
Rated motor current
Simple
Simple
Simple
DC injection brake
0 to 120 Hz, 9999
operation frequency
DC injection brake
0 to 10 s, 8888
operation time
DC injection brake
0 to 30%
operation voltage
Starting frequency
0 to 60 Hz
Load pattern selection
0, 1, 12 to 15
0 to 590 Hz
Jog frequency
Simple
Simple
Simple
Jog acceleration/
0 to 3600 s
deceleration time
Simple
Simple
Simple
MRS input selection
0, 2, 4
High speed maximum
0 to 590 Hz
frequency
Base frequency voltage
0 to 1000 V, 8888,
9999
Acceleration/
1 to 590 Hz
deceleration reference
frequency
Acceleration/
0, 1
deceleration time
increments
Stall prevention
0 to 400%
operation level
Stall prevention
0 to 200%, 9999
operation level
compensation factor at
double speed
Multi-speed setting
0 to 590 Hz, 9999
(speed 4 to speed 7)
Setting range
Minimum
setting
increments
0.1%
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.1 s
0.1 s
*2
0.01 A
*3
0.1 A
0.01 Hz
0.1 s
0.1%
0.01 Hz
1
0.01 Hz
0.1 s
1
0.01 Hz
0.1 V
0.01 Hz
1
0.1%
0.1%
0.01 Hz
Initial value
Refer
Customer
to
setting
page
*1
538
3%
*1
2%
*1
1%
253
*2
120 Hz
*3
60 Hz
0 Hz
253
60 Hz
539
60 Hz
226
30 Hz
226
10 Hz
226
190
*4
5 s
*5
15 s
190
*4
10 s
*5
30 s
Inverter rated
230,
current
353,
363
3 Hz
546
0.5 s
546
1%
546
0.5 Hz
201,
202
1
541
5 Hz
224
0.5 s
224
0
346
*2
253
120 Hz
*3
60 Hz
9999
539
60 Hz
190
0
190
110%
257
9999
257
9999
226
5. PARAMETERS
5.1 Parameter List
3
4
5
5
5
6
7
8
9
10
109

Advertisement