Mitsubishi Electric 800 Series Instruction Manual page 90

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
Pr.
Name
group
79
D000
Operation mode
selection
125
T022
Terminal 2 frequency
setting gain
frequency
126
T042
Terminal 4 frequency
setting gain
frequency
160
E440
User group read
selection
934
A630
PID display bias
coefficient
934
A631
PID display bias
analog value
935
A632
PID display gain
coefficient
935
A633
PID display gain
analog value
991
E105
PU contrast
adjustment
998
E430
PM parameter
initialization
999
E431
Automatic parameter
setting
1136
A670
Second PID display
bias coefficient
1137
A671
Second PID display
bias analog value
1138
A672
Second PID display
gain coefficient
1139
A673
Second PID display
gain analog value
*1
Initial value for the FR-F860-00027.
*2
Initial value for the FR-F860-00061 and FR-F860-00090.
*3
Initial value for the FR-F860-00170 or higher.
*4
For the FR-F860-00680 or lower.
*5
For the FR-F860-01080 or higher.
*6
Initial value for the FR-F860-00090 or lower.
Unit
Initial
Range
value
1
0
0 to 4, 6, 7
0.01 Hz
60 Hz
0 to 590 Hz
0.01 Hz
60 Hz
0 to 590 Hz
1
0
0, 1, 9999
0.01
9999
0 to 500,
9999
0.1%
20%
0 to 300%
0.01
9999
0 to 500,
9999
0.1%
100%
0 to 300%
1
58
0 to 63
1
0
0, 8009,
8109, 9009,
9109
1
9999
1, 2, 10, 11,
12, 13, 20,
21, 9999
0.01
9999
0 to 500,
9999
0.1%
20%
0 to 300%
0.01
9999
0 to 500,
9999
0.1%
100%
0 to 300%
Application
Select the start and frequency command
sources.
Allows the frequency at the maximum
potentiometer setting (5 V in the initial setting) to
be changed.
Allows the frequency at the maximum current
input (20 mA in the initial setting) to be changed.
Restricts the parameters that are read by the
operation panel and the parameter unit.
Adjust the bias value and the gain value that are
displayed in relation to PID control.
Contrast adjustment of the operation panel and
the parameter unit can be performed.
Selects the PM sensorless vector control and
set the parameters that are required to drive a
PM motor.
Changes parameter settings as a batch. The
target parameters include communication
parameters for the Mitsubishi Electric human
machine interface (GOT) connection and the
parameters for the rated frequency settings of
50 Hz/60 Hz.
Adjust the bias value and the gain value that are
displayed in relation to second PID control.
4.1 Frequently-used parameters (simple mode parameters)
Refer to
page
3
204
101,
328
4
103,
328
5
177
421
4
5
165
6
151
7
173
8
421
9
10
89
4. BASIC OPERATION