 Tuning the second applied motor
• When one inverter switches the operation between two different motors, set the second motor in Pr.450 Second applied
motor. (Refer to
• Turning ON the RT signal will enable the parameter settings for the second motor as shown below.
Function
Motor capacity
Number of motor poles
Motor excitation current
Rated motor voltage
Rated motor frequency
Motor constant (R1)
Motor constant (R2)
Motor constant (L1)/d-axis
inductance (Ld)
Motor constant (L2)/q-axis
inductance (Lq)
Motor constant (X)
Auto tuning setting/status
Frequency search gain
NOTE
• The RT signal is assigned to the terminal RT in the initial status. Set "3" in any of Pr.178 to Pr.189 (Input terminal function
selection) to assign the RT signal to another terminal.
• Changing the terminal assignment using Pr.178 to Pr.189 (Input terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr.1 Maximum frequency
Pr.9 Electronic thermal O/L relay
Pr.31 to Pr.36 Frequency jump
Pr.71 Applied motor
Pr.156 Stall prevention operation selection
Pr.178 to Pr.189 (Input terminal function selection)
Pr.190 to Pr.196 (Output terminal function selection)
362
5. PARAMETERS
5.10 (C) Motor constant parameters
page
351.) In the initial setting, no second motor is applied.
RT signal ON (second motor)
Pr.453
Pr.454
Pr.455
Pr.456
Pr.457
Pr.458
Pr.459
Pr.460
Pr.461
Pr.462
Pr.463
Pr.560
page 253
page 230
page 255
page 351
page 257
RT signal OFF (first motor)
Pr.80
Pr.81
Pr.82
Pr.83
Pr.84
Pr.90
Pr.91
Pr.92
Pr.93
Pr.94
Pr.96
Pr.298
page 343
page 297