Mitsubishi Electric 800 Series Instruction Manual page 286

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Monitor item
Increment and
*2
0.01 kW/0.1
Output power
kW
Load meter
0.1%
Motor excitation current
0.0 1 A/0.1 A
Reference voltage output
Motor load factor
0.1%
Motor output
0.01 kW/0.1
kW
Energy saving effect
Changeable by
parameter
setting
PID set point
0.1%
PID measured value
0.1%
PID deviation
0.1%
Motor thermal load factor
0.1%
Inverter thermal load factor 0.1%
PID measured value 2
0.1%
PID input pressure value
0.1%
PLC function analog
0.1%
output
BACnet terminal CA
0.1%
output level
BACnet terminal AM
0.1%
output level
Remote output value 1
0.1%
Remote output value 2
0.1%
Remote output value 3
0.1%
Remote output value 4
0.1%
PID manipulated variable
0.1%
Second PID set point
0.1%
Second PID measured
0.1%
value
Second PID deviation
0.1%
Second PID measured
0.1%
value 2
Second PID manipulated
0.1%
variable
Control circuit temperature 1°C
*1
Differs according to capacities. (FR-F860-00680 or lower/FR-F860-01080 or higher)
*2
When the output current is less than the specified current level (5% of the inverter rated current), the output current is monitored as 0 A. Therefore,
the monitored value of an output current and output power may be displayed as "0" when using a much smaller-capacity motor compared to the
inverter or in other instances that cause the output current to fall below the specified value.
*3
Setting of Pr.1018 Monitor with sign selection is required.
*4
The setting is available only with terminal AM (Pr.158).
*5
The setting is available only with terminal CA (Pr.54).
Pr.54 (CA)
unit
Pr.158 (AM)
setting
14
*1
17
*1
18
21
24
34
*1
50
52
53
*4
54
61
62
67
69
70
*5
85
*4
86
87
88
89
90
*4
91
92
93
*4
94
95
*4
96
98
Terminal CA/AM
Negative
full-scale value
(-) output
Inverter rated power  2
Pr.866
Pr.56
200%
Rated motor capacity
Inverter capacity
100%
100%
100%
Motor thermal operation
level (100%)
Inverter thermal operation
level (100%)
100%
100%
100%
100%
100%
1000%
1000%
1000%
1000%
100%
100%
100%
200%
100%
100%
100°C
5.8 (M) Monitor display and monitor output signal
Remarks
Terminal CA: output is 20 mA
Terminal AM: output is 10 V.
Regarding the energy saving
monitor, refer to
page 291
Refer to
page 410
for the PID
control.
Refer to
page 410
for the PID
control.
Displays the input pressure
value of the PID input
pressure control function.
Refer to
page 463
for the PLC
function.
The value set in the Analog
Output object (ID=0: Terminal
CA) for BACnet
communication is output.
The value set in the Analog
Output object (ID=1: Terminal
AM) for BACnet
communication is output.
(The output is always
negative regardless of the
Pr.290 setting when the
monitored value is negative.)
Refer to
page 312
for the
analog remote output.
Refer to
page 410
for the PID
control.
Terminal CA: 0 to 100°C
terminal AM: -20 to 100°C
285
5. PARAMETERS
3
4
5
5
5
6
7
8
9
10

Advertisement

Table of Contents
loading

Table of Contents