 Registering a parameter in a user group (Pr.173)
• To register Pr.3 in a user group
Operating procedure
1.
Power ON
Make sure the motor is stopped.
2.
Changing the operation mode
Select the PU operation mode.
3.
Selecting the parameter number
Read Pr.173.
4.
Parameter registration
Set "3" in Pr.173.
Pr.3 is registered in the user group.
 Clearing a parameter from a user group (Pr.174)
• To delete Pr.3 from a user group
Operating procedure
1.
Power ON
Make sure the motor is stopped.
2.
Changing the operation mode
Select the PU operation mode.
3.
Selecting the parameter number
Read Pr.174.
4.
Clearing the parameter
Set "3" in Pr.173.
Pr.3 is deleted from the user group.
NOTE
• Pr.77 Parameter write selection, Pr.160, Pr.296 Password lock level, Pr.297 Password lock/unlock and Pr.991 PU
contrast adjustment can always be read regardless of the user group setting.
• Pr.77, Pr.160, Pr.172 to Pr.174, Pr.296, Pr.297 cannot be registered in a user group.
• When Pr.174 is read, "9999" is always displayed. "9999" can be written, but it does not function.
• Pr.172 is disabled if set to a value other than "9999".
Parameters referred to
Pr.77 Parameter write selection
Pr.296 Password lock level, Pr.297 Password lock/unlock
Pr.550 NET mode operation command source selection
Pr.551 PU mode operation command source selection
178
5. PARAMETERS
5.4 (E) Environment setting parameters
page 168
page 214
page 214
page 170