Pr.
Register
932
41932
Terminal 4 bias command (torque)
932
42122
Terminal 4 bias (torque)
43932
Terminal 4 bias (torque) (terminal
analog value)
933
41933
Terminal 4 gain command (torque)
933
42123
Terminal 4 gain (torque)
43933
Terminal 4 gain (torque) (terminal
analog value)
934
41934
PID display bias coefficient
934
42124
PID display bias analog value
43934
PID display bias analog value
(terminal analog value)
935
41935
PID display gain coefficient
935
42125
PID display gain analog value
43935
PID display gain analog value
(terminal analog value)
1000 to
45000 to
For details on parameter names, refer
1999
45999
to the parameter list
• Fault history
Register
Definition
40501
Fault record 1
40502
Fault record 2
40503
Fault record 3
40504
Fault record 4
40505
Fault record 5
40506
Fault record 6
40507
Fault record 7
40508
Fault record 8
• Model information monitor
Register
44001
Model (First and second characters)
44002
Model (Third and fourth characters)
44003
Model (Fifth and sixth characters)
44004
Model (Seventh and eighth characters)
44005
Model (Ninth and tenth characters)
44006
Model (Eleventh and twelfth characters)
44007
Model (Thirteenth and fourteenth characters)
44008
Model (Fifteenth and sixteenth characters)
44009
Model (Seventeenth and eighteenth characters)
44010
Model (Nineteenth and twentieth characters)
44011
Capacity (First and second characters)
44012
Capacity (Third and fourth characters)
44013
Capacity (Fifth and sixth characters)
NOTE
• When a 32-bit parameter setting or monitored value is read and the read value exceeds HFFFF, the reply data will be
HFFFF.
Name
(page
108).
Read/Write
Read/Write
Read
Read
Read
Read
Read
Read
Read
Definition
Read/Write
Read/Write
Read/Write
Analog value (%) set to Pr.932
Read
Analog value (%) of current (voltage) applied to
terminal 4
Read/Write
Read/Write
Analog value (%) set to Pr.933
Read
Analog value (%) of current (voltage) applied to
terminal 4
Read/Write
Read/Write
Analog value (%) set to Pr.934
Read
Analog value (%) of current (voltage) applied to
terminal 4
Read/Write
Read/Write
Analog value (%) set to Pr.935
Read
Analog value (%) of current (voltage) applied to
terminal 4
Read/Write
The parameter number + 44000 is the register number.
Remarks
Data is 2 bytes and so is stored in "H00".
The lowest 1 byte can be referred to for the error code.
(For details on error codes, refer to
The fault history is batch-cleared by writing to register
40501.
Set any value for the data.
Read/Write
Read
Reading inverter type in ASCII code.
"H20" (blank code) is set for blank area.
Read
Example of FR-F860-3
Read
H46, H52, H2D, H46, H38, H36, H30, H2D,
Read
H33, H20......H20
Read
Read
Read
Read
Read
Read
Read
The capacity in the inverter model can be
read in ASCII code.
Data is read in increments of 0.1 kW, and
Read
rounds down to 0.01 kW increments.
"H20" (blank code) is set for blank area.
Example
Read
0.75K........."7"
(H20, H20, H20, H20, H20, H37)
5.12 (N) Operation via communication and its settings
Remarks
page
568.)
Remarks
5. PARAMETERS
3
4
5
5
5
6
7
8
9
10
513