Mitsubishi Electric 800 Series Instruction Manual page 345

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Setting
Signal
name
6
CS
7
OH
8
REX
10
X10
11
X11
12
X12
13
X13
14
X14
16
X16
18
X18
24
MRS
25
STP
(STOP)
28
X28
33
PWS
37
X37
38
PDI1
39
PDI2
40
PDI3
46
TRG
47
TRC
48
X48
50
SQ
51
X51
57
JOGF
58
JOGR
60
STF
61
STR
62
RES
64
X64
65
X65
66
X66
67
X67
70
X70
71
X71
72
X72
73
X73
77
X77
78
X78
79
X79
80
X80
81
PGT
84
X84
92
X92
94
X94
95
X95
96
X96
97
X97
98
X98
344
5. PARAMETERS
5.9 (T) Multi-Function Input Terminal Parameters
Function
Selection of automatic restart after instantaneous power
failure, flying start
Electronic bypass function
*2
External thermal relay input
15-speed selection (Combination with multi-speeds of RL,
RM, and RH)
Inverter run enable signal (FR-CC2 connection)
FR-CC2 connection, instantaneous power failure detection
PU operation external interlock
External DC injection brake operation start
PID control valid terminal
PU/External operation switchover (External operation with
X16-ON)
V/F switchover (V/F control with X18-ON)
Output stop
Electronic bypass function
Start self-holding selection
Start-time tuning start external input
Phase synchronization command for bypass switching
Traverse function selection
PID multistage set point setting 1
PID multistage set point setting 2
PID multistage set point setting 3
Trace trigger input
Trace sampling start/end
Power failure stop external
Sequence start
Fault clear
JOG forward rotation command
JOG reverse rotation command
Forward rotation command (Assignable to the STF terminal
(Pr.178) only)
Reverse rotation command (Assignable to the STR terminal
(Pr.179) only)
Inverter reset
During retry
PU/NET operation switchover (PU operation with X65-ON)
External/NET operation switchover (NET operation with
X66-ON)
Command source switchover (Command by Pr.338, Pr.339
enabled with X67-ON)
DC feeding operation permission
*3
DC feeding cancel
PID P control switchover
Second PID P control switchover
Pre-charge end command
Second pre-charge end command
Second PID forward/reverse action switchover
Second PID control valid terminal
PID gain tuning start/forced end
Emergency drive execution command
Emergency stop
Control signal input for main circuit power supply MC
Converter unit fault input
Converter unit fault (E.OHT, E.CPU) input
Cleaning valid
Cleaning trigger
Pr.57, Pr.58, Pr.162 to Pr.165, Pr.299,
Pr.611
Pr.57, Pr.58, Pr.135 to Pr.139, Pr.159
Pr.9
Pr.4 to Pr.6, Pr.24 to Pr.27, Pr.232 to
Pr.239
Pr.30, Pr.599
Pr.30
Pr.79
Pr.10 to Pr.12
Pr.127 to Pr.134, Pr.575 to Pr.577
Pr.79, Pr.340
Pr.80, Pr.81, Pr.800
Pr.17
Pr.57, Pr.58, Pr.135 to Pr.139, Pr.159
Pr.250
Pr.95
Pr.139
Pr.592 to Pr.597
Pr.1460 to Pr.1466
Pr.1020 to Pr.1047
Pr.1020 to Pr.1047
Pr.261 to Pr.266, Pr.294, Pr.668
Pr.414
Pr.414
Pr.15, Pr.16
Pr.250
Pr.250
Pr.75
Pr.127 to Pr.134
Pr.79, Pr.340
Pr.79, Pr.340
Pr.338, Pr.339
Pr.30
*3
Pr.30
Pr.127 to Pr.134, Pr.575 to Pr.577
Pr.127 to Pr.134, Pr.575 to Pr.577
Pr.760 to Pr.764
Pr.765 to Pr.769
Pr.753 to Pr.758
Pr.753 to Pr.758
Pr.1211 to Pr.1219
Pr.514, Pr.515, Pr.523, Pr.524, Pr.1013
*3
Pr.1103
Pr.30, Pr.137, Pr.248, Pr.254
Pr.57, Pr.58, Pr.135 to Pr.139, Pr.159
Pr.1469 to Pr.1479
Related parameter
Refer to
page
448
376
230
226
553
553
204
546
396
204
145
346
376
550
371
*4
389
396
466
466
458
463
*5
463
224
550
550
162
396
204
204
214
553
553
396
396
424
424
396
396
415
245
190
385
376
391