5.4.6
Direct setting
The PID action set point setting screen can be displayed quickly on the monitor.
Pr.
1000
Direct setting selection
E108
• The monitor display can be switched from the Main monitor screen to the set point setting screen for the PID action by
simply
operation, according to the setting of Pr.1000 Direct setting selection. On each setting screen, turn
input a setting value, and press
Example of screen switching and shifting when the PID control is enabled (Pr.128 ≠ "0")
Output frequency
0.00
STOP
PREV
SET
One of the Main monitor screen
*1
When Pr.1000="0"
*2
When Pr.1000="1"
*3
When Pr.1000="2"
*4
Not displayed when PID control is disabled (Pr.128="0").
*5
Indication of [NEXT] is not displayed when Pr.1000="0".
• To switch back the monitor display from the direct screen or the Frequency setting screen to the Main monitor screen, press
.
(BACK)
NOTE
• For the availability of the direct setting for your operation panel, refer to your FR-LU08 Instruction Manual.
Parameters referred to
Pr.128 PID action selection
5.4.7
Resetting USB host errors
When a USB device is connected to the USB connector (connector A), the USB host error can be canceled without performing
an inverter reset.
Pr.
1049
USB host reset
E110
• Parameter copy and the trace function can be used when a USB device (such as a USB memory) is connected to the USB
connector (connector A). (Refer to
• When a device such as a USB charger is connected to the USB connector and an excessive current (500 mA or higher)
flows, USB host error (UF warning) is displayed on the operation panel.
• If a UF warning occurs, disconnect the USB device and set Pr.1049="1" to cancel the USB error. (The UF warning can
also be canceled by resetting the inverter power or resetting with the RES signal.)
166
5. PARAMETERS
5.4 (E) Environment setting parameters
Name
Initial value
0
to confirm the setting.
(SET)
∗2,∗3
PID act set pnt
1 2 : 3 4
Pres value
10.0PSI
Set value
10.0PSI
Hz
STOP
PU
NEXT
BACK
SET
Direct #1 screen ∗4
∗1
page 396
Name
0
page
67.)
Setting range
0
1
2
∗2,∗3
2ndPID set point
Pres value
(NEXT)
Set value
PU
STOP
N E X T
NEXT
BACK
SET
Direct #2 screen ∗4
Initial value
Setting range
0
1
Description
Displays the Frequency setting screen.
Displays the direct (set point setting) screen.
Displays the direct (set point setting) screen and
the Frequency setting screen.
∗3
Frequency Setting
10.0PSI
Pres value
10.0PSI
(NEXT)
Set value
PU
STOP
N E X T
NEXT
BACK
Frequency setting screen ∗5
∗2
(NEXT)
(NEXT)
Description
Read only
Resets the USB host.
to
0.00Hz
100.00Hz
PU
SET
N E X T
NEXT
∗3

Advertisement

Table of Contents
loading

Table of Contents