Mitsubishi Electric 800 Series Instruction Manual page 352

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

5.10.1
Applied motor
By setting the applied motor type, the thermal characteristic appropriate for the motor can be selected.
When using a constant-torque or PM motor, the electronic thermal O/L relay is set according to the used motor.
Pr.
Name
71
Applied motor
C100
450
Second applied
C200
motor
 Setting the applied motor
• Refer to the following list and set the parameters according to the applied motor.
Pr.71
Pr.450
Motor
0
Standard motor
(Pr.71 initial
value)
1
Constant-torque motor
2
Standard motor
Adjustable 5 points V/F (Refer
to
page
544.)
8090
IPM motor
9090
SPM motor
*3
Standard motor
3 (4)
Constant-torque motor
*3
13 (14)
IPM motor
*3
8093 (8094)
SPM motor
*3
9093 (9094)
5
Standard motor
15
Constant-torque motor
6
Standard motor
16
Constant-torque motor
9999
No second applied motor
(initial
value)
*1
For the FR-F860-00680 or lower.
*2
For the FR-F860-01080 or higher.
*3
The same operation is performed for the both settings.
Initial value
Setting range
0
0 to 6, 13 to 16, 8090, 8093, 8094,
9090, 9093, 9094
9999
0, 1, 3 to 6, 13 to 16, 8090, 8093,
8094, 9090, 9093, 9094
9999
Constant value range when performing
offline auto tuning (increment)
Pr.82 (Pr.455) and Pr.859 (Pr.860)
• 0 to 500 A, 9999 (0.01 A)
• 0 to 3600 A, 9999 (0.1 A)
Pr.90 (Pr.458) and Pr.91 (Pr.459)
• 0 to 50 Ω, 9999 (0.001 Ω)
• 0 to 400 mΩ, 9999 (0.01 mΩ)
Pr.92 (Pr.460) and Pr.93 (Pr.461) (Induction
motor)
• 0 to 6000 mH, 9999 (0.1 mH)
• 0 to 400 mH, 9999 (0.01 mH)
Pr.92 (Pr.460) and Pr.93 (Pr.461) (PM motor)
• 0 to 500 mH, 9999 (0.01 mH)
• 0 to 50 mH, 9999 (0.001 mH)
Pr.94 (Pr.462)
• 0 to 100%, 9999 (0.1%)
• 0 to 100%, 9999 (0.01%)
Pr.706 (Pr.738)
• 0 to 5000 mV/(rad/s), 9999 (0.1 mV/(rad/s))
Pr.82 (Pr.455), Pr.859 (Pr.860), Pr.90
(Pr.458), Pr.91 (Pr.459), Pr.92 (Pr.460), Pr.93
(Pr.461), Pr.94 (Pr.462) and Pr.706 (Pr.738)
• Internal data value 0 to 65534, 9999 (1)
The display increment can be changed in
Pr.684.
Star
Pr.82 (Pr.455) and Pr.859
connectio
(Pr.860)
n
• 0 to 500 A, 9999 (0.01 A)
• 0 to 3600 A, 9999 (0.1 A)
Pr.90 (Pr.458) and Pr.91 (Pr.459)
• 0 to 50 Ω, 9999 (0.001 Ω)
Delta
• 0 to 400 mΩ, 9999 (0.01 mΩ)
connectio
n
Pr.92 (Pr.460) and Pr.93 (Pr.461)
• 0 to 50 Ω, 9999 (0.001 Ω)
• 0 to 3600 mΩ, 9999 (0.1 mΩ)
Pr.94 (Pr.462)
• 0 to 500 Ω, 9999 (0.01 Ω)
• 0 to 100 Ω, 9999 (0.01 Ω)
By selecting a motor, the thermal characteristic
and motor constant of each motor are set.
Set it when using the second motor.
(the same specifications as Pr.71)
The function is disabled.
Operational characteristic of the
electronic thermal O/L relay
Standard
*1
*2
*1
*2
*1
*2
*1
*2
*1
*2
*1
*2
*1
*2
*1
*2
*1
*2
5.10 (C) Motor constant parameters
Description
Constant-torque
351
5. PARAMETERS
3
4
5
5
5
6
7
8
9
10

Advertisement

Table of Contents
loading

Table of Contents