Pr.
Name
1413
Second motor induced voltage
C235
constant (phi f) exponent
739
Second motor Ld decay ratio
C231
740
Second motor Lq decay ratio
C232
741
Second starting resistance
C282
tuning compensation
742
Second motor magnetic pole
C285
detection pulse width
746
Second motor protection
C233
current level
*1
For the FR-F860-00680 or lower.
*2
For the FR-F860-01080 or higher.
*3
The setting range and unit change according to the Pr.71 (Pr.450) setting.
• The settings are valid under the PM motor control.
• The offline auto tuning enables the operation with SPM motors and IPM motors. (When a PM motor is used,
always perform the offline auto tuning.)
• Tuning is enabled even when a load is connected to the motor.
• Reading/writing of the motor constants tuned by offline auto tuning are enabled. The offline auto tuning data
(motor constants) can be copied to another inverter with the operation panel.
• The offline auto tuning status can be monitored with the operation panel and the parameter unit.
Initial
Setting range
value
9999
0 to 2
9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
9999
0 to 6000 μs, 10000 to 16000 μs,
9999
9999
100 to 500%
9999
Description
Set the exponent n when the induced
voltage constant phi f (Pr.738) is multiplied
n
by 10
.
No exponent setting
Tuning data of the second motor.
(The value measured by offline auto
tuning is automatically set.)
9999: The inverter internal data is used.
Tuning data of the second motor.
(The value measured by offline auto
tuning is automatically set.)
9999: The inverter internal data is used.
Set the maximum current (OCT) level of
the second motor.
Maximum current level of the motor: 200%
5. PARAMETERS
5.10 (C) Motor constant parameters
3
4
5
5
5
6
7
8
9
10