Mitsubishi Electric 800 Series Instruction Manual page 137

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
Pr.
group
H016
608
Second motor permissible load
level
H020
561
PTC thermistor protection level
H021
1016
PTC thermistor protection
detection time
H100
244
Cooling fan operation selection
H101
249
Earth (ground) fault detection at
start
H103
997
Fault initiation
H106
244
Cooling fan operation selection
during the test operation
H194
521
Output short-circuit detection
H200
251
Output phase loss protection
selection
H201
Input phase loss protection
*1
872
selection
H300
65
Retry selection
H301
67
Number of retries at fault
occurrence
H302
68
Retry waiting time
H303
69
Retry count display erase
H320
Emergency drive mode selection
*1
523
H321
Emergency drive running speed
*1
524
H322
Emergency drive dedicated retry
*1
515
count
H323
Running speed after emergency
*1
1013
drive retry reset
H324
Emergency drive dedicated retry
*1
514
waiting time
H325
890
Internal storage device status
indication
H400
1
Maximum frequency
H401
2
Minimum frequency
H402
18
High speed maximum frequency
H420
31
Frequency jump 1A
H421
32
Frequency jump 1B
H422
33
Frequency jump 2A
H423
34
Frequency jump 2B
H424
35
Frequency jump 3A
H425
36
Frequency jump 3B
H429
552
Frequency jump range
H500
22
Stall prevention operation level
(Torque limit level)
H501
156
Stall prevention operation
selection
H520
1480
Load characteristics measurement
mode
H521
1481
Load characteristics load reference
1
H522
1482
Load characteristics load reference
2
H523
1483
Load characteristics load reference
3
H524
1484
Load characteristics load reference
4
H525
1485
Load characteristics load reference
5
H526
1486
Load characteristics maximum
frequency
136
5. PARAMETERS
5.1 Parameter List
Name
Refer
to
page
230
230
230
237
238
240
237
240
241
241
242
242
242
242
245
245
245
245
245
253
253
Simple
Simple
Simple
253
Simple
Simple
Simple
253
255
255
255
255
255
255
255
257
257
265
265
265
265
265
265
265
Pr.
Pr.
group
H527
1487
Load characteristics minimum
frequency
H531
1488
Upper limit warning detection width
H532
1489
Lower limit warning detection width
H533
1490
Upper limit fault detection width
H534
1491
Lower limit fault detection width
H535
1492
Load status detection signal delay
time / load reference measurement
waiting time
H600
48
Second stall prevention operation
level
H601
49
Second stall prevention operation
frequency
H610
23
Stall prevention operation level
compensation factor at double
speed
H611
66
Stall prevention operation
reduction starting frequency
H620
148
Stall prevention level at 0 V input
H621
149
Stall prevention level at 10 V input
H631
154
Voltage reduction selection during
stall prevention operation
H710
815
Torque limit level 2
H730
874
OLT level setting
H800
374
Overspeed detection level
 M: Monitor display and monitor
output signal
Parameters regarding the inverter's operating status. These
parameters are used to set the monitors and output signals.
Pr.
Pr.
group
M000
37
Speed display
M001
505
Speed setting reference
M002
144
Speed setting switchover
M020
170
Watt-hour meter clear
M021
563
Energization time carrying-over
times
M022
268
Monitor decimal digits selection
M023
891
Cumulative power monitor digit
shifted times
M030
171
Operation hour meter clear
M031
564
Operating time carrying-over times
M040
55
Frequency monitoring reference
M041
56
Current monitoring reference
M042
866
Torque monitoring reference
M043
241
Analog input display unit
switchover
M044
290
Monitor negative output selection
M045
1018
Monitor with sign selection
M050
1106
Torque monitor filter
M051
1107
Running speed monitor filter
M052
1108
Excitation current monitor filter
M060
663
Control circuit temperature signal
output level
M100
52
Operation panel main monitor
selection
Name
Refer
to
page
265
265
265
265
265
265
257
257
257
257
257
257
257
190
257
270
Name
Refer
to
page
272
272
272
274
274
274
274,
291
274
274
284
284
284
328
274,
284
274
274
274
274
316
274