 GOT initial setting (PU connector) (Pr.999 = "10, 12")
Pr.
79
Operation mode selection
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting
124
PU communication CR/LF selection
340
Communication startup mode selection
414
PLC function operation selection
*1
The setting is changed when Pr.414 = "0" (initial setting).
 Initial setting with the GOT2000 series
• When "FREQROL 500/700/800, SENSORLESS SERVO" is selected for "Controller Type" in the GOT setting, set Pr.999
= "10" to configure the GOT initial setting.
• When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT setting, the GOT automatic
connection can be used. When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT
setting and the GOT automatic connection is not used, set Pr.999 = "12" to configure the GOT initial setting. (Refer to
533)
 Initial setting with the GOT1000 series
• Set Pr.999 = "10" to configure the GOT initial setting.
NOTE
• Always perform an inverter reset after the initial setting.
• For details on connection with GOT, refer to the Instruction Manual of GOT.
 GOT initial setting (RS-485 terminals) (Pr.999 = "11, 13")
Pr.
79
Operation mode selection
332
RS-485 communication speed
333
RS-485 communication stop bit length
334
RS-485 communication parity check selection
335
RS-485 communication retry count
336
RS-485 communication check time interval
337
RS-485 communication waiting time setting
340
Communication startup mode selection
341
RS-485 communication CR/LF selection
414
PLC function operation selection
549
Protocol selection
*1
The setting is changed when Pr.414 = "0" (initial setting).
 Initial setting with the GOT2000 series
• When "FREQROL 500/700/800, SENSORLESS SERVO" is selected for "Controller Type" in the GOT setting, set Pr.999
= "11" to configure the GOT initial setting.
• When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT setting, the GOT automatic
connection can be used. When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT
setting and the GOT automatic connection is not used, set Pr.999 = "13" to configure the GOT initial setting. (Refer to
533)
Name
Initial value
0
192
1
2
1
9999
9999
1
0
0
Name
Pr.999="10"
Pr.999="12"
1
1
192
1152
10
0
1
1
9999
9999
9999
9999
0 ms
0 ms
1
1
0
0
*1
2
Initial
Pr.999="11"
Pr.999="13"
value
0
0
0
96
192
1152
1
10
0
2
1
1
1
9999
9999
0 s
9999
9999
9999
0 ms
0 ms
0
1
1
1
1
1
0
*1
2
0
0
0
5.4 (E) Environment setting parameters
3
Refer to page
204
483
4
5
213
5
463
5
6
page
7
8
9
10
Refer to page
204
483
213
483
463
500
page
175
5. PARAMETERS